Issue | Error The length of the source exceeds the size of the destination buffer when using Windows Authentication with Jet Reports Connection |
Solution |
There is an issue with Navision 3.60 SQL, CFront 3.60 and Windows Authentication. This was corrected by executable hotfix 28 and the subsequent release of 3.60A. Applying hotfix 28 does not change the version setting in the database and can therefore be rolled out over a period of time without affecting other clients from opening the database. Database object modifications are not impacted by this hotfix (no code merge required). |